- Supports 2 door control. It can connect with access controller via RS-485
- Connects with card reader via RS-485 (OSDP) or Wiegand
- Installs with guide rail
- Supports battery charging and discharging
- Supports indicators for indicating power status, communciation status, running status, and door staus
System |
|
Operating system |
MCU |
Interface |
|
Lock control |
2 |
Exit button |
2 |
Door contact input |
2 |
Alarm input |
4 |
Alarm output |
2 |
TAMPER |
1 |
RS-485 |
4, 2 for card reader, 2 for access controller |
Wiegand |
2, standard 26/34 input, supports custom Wiegand settings |
Capacity |
|
Linked door capacity |
2 doors |
Linked card reader capaciry |
4 RS-485 card readers (OSDP protocol) and 2 Wiegand card readers |
General |
|
Indicator |
6 indicators, 1 for indicating power status, 1 for running status, 2 for communication status, and 2 for door status |
Battery |
Charge and discharge |
Power supply |
12 ± 15% VDC |
Power consumption |
</= 50 W |
Working temperature |
-10 °C to 55 °C (14 °F to 131 ° F) |
Working humidity |
0% to 90% (No condensing) |
Installation |
Installation with guide rail |
Function |
|
Configuration via Web browser |
Support via access controller |
Multi-factor authentication |
Support via access controller |
First person in |
Support via access controller |
Multi-door interlocking |
Support via access controller: supports 32 groups (32 doors each) |